Sets the SemiQuant factor, base mass, and reported mass (isotope).
If the Batch contains a sample of the “SQStd” type, SemiQuant factor correction is performed based on the SemiQuant Factor settings in this dialog box. SemiQuant factor correction is only performed for elements that have the base mass and the SemiQuant Factor specified in this dialog box.
Elements (isotopes) that are displayed in the Batch Table and/or reported in the analysis results report are set in this dialog box as the “Reported Mass“.
To view the SemiQuant factor curve for the elements, use the “SemiQuant Factor pane“.
Title
Displays the title. (Editable)
Minimum Peak
Enter the minimum peak value in CPS. When IntelliQuant is set to On, the minimum peak is always “3000cps”.
Conc. Unit
Select the unit for the concentration from the list. This unit is used for reports. Select [Auto] to automatically select the unit that is most appropriate for the concentration.
SemiQuant Factor and Reported Mass Table
The following columns appear in the table (click on column heading to sort the table using the values in the selected column).
Load File
Opens the [Load SQ Parameters File] dialog box, which lets you open a SemiQuant parameters file.
Save As
Opens the [Save SQ Parameters File As] dialog box, which lets you save the configured SemiQuant parameters file with a different name.
Reset to Default He Mode
Restores the default SemiQuant Basic Parameters settings for the He mode.
Reset to Default No Gas Mode
Restores the default SemiQuant Basic Parameters settings for standard (no gas) mode.
Export Table
Opens the [Export Table] (Entire Table) dialog box, which lets you export the entire table.
Export Selected Area
Run this command after you select an area to export. The [Export Table] (Area) dialog box is displayed, which lets you export the data for the selected area.
Copy
Copies the selected data to the Clipboard. Copies the selected rows or columns.
Paste
Pastes the data from the Clipboard to the selected location.
Reset Sort
Restores the default sort order for the table.
Fill Down
Run this command after selecting multiple cells to copy the value in the top cell to the rest of the selected cells.
Opens the [Print] dialog box, which lets you print the contents of the selected pane.
Print Preview
Opens the [Print Preview] dialog box, which displays the print preview.
Atomic Number
Displays the atomic number.
Element
Displays the element name.
SemiQuant Factor
Enter the SemiQuant factor. By default, elements that cannot be detected by this instrument are left blank.
Base Mass
Select the base mass from the list. You can also select the isotope masses. By default, elements that cannot be detected by this instrument are left blank.
Reported Mass
Click the button in the cell, select the masses to include in the Batch Table and the report. Mark the [All] check box to specify the mass for all isotopes.
Right-click on the table to display the following context menu.