Task Navigator

[Hardware] group

[Dashboard]

Opens the Dashboard Pane and the Early Maintenance Feedback Pane.

[Performance Report]

This menu is displayed when the [Mainframe] check box is selected in the Dashboard Pane.

Opens the Performance Report Pane.

[Maintenance Log]

This menu is displayed when the [Mainframe] check box is selected in the Dashboard Pane.

Opens the Maintenance Log Pane.

[Nebulizer Test]

This menu is displayed when the [Sample Introduction] check box is selected in the Dashboard Pane.

Opens the Nebulizer Test Pane.

[Torch Axis Setting]

This menu is displayed when the [Plasma] check box is selected in the Dashboard Pane.

Opens the Torch Axis Setting Pane.

[Plasma Correction]

This menu is displayed when the [Plasma] check box is selected in the Dashboard Pane.

Opens the Plasma Correction Pane.

[Gas Purge Setting]

This menu is displayed when the [Plasma] check box is selected in the Dashboard Pane.

Opens the Gas Purge Setting Pane.

[Ion Lenses Maintenance]

This menu is displayed when the [Ion Lenses] check box is selected in the Dashboard Pane.

Ion Lenses Maintenance Pane.

[Cell Maintenance]

This menu is displayed when the [Collision/Reaction Cell] check box is selected in the Dashboard Pane.

Opens the Cell Maintenance Pane.

[Resolution / Axis]

TThis menu is displayed when the [Quadrupole] check box is selected in the Dashboard Pane.

Opens the Resolution / Axis Setting Pane.

[Q1 Resolution / Axis]

This menu is displayed when the [Q1] check box is selected in the Dashboard Pane.

Opens the Resolution / Axis Setting Pane.

[Q2 Resolution / Axis]

This menu is displayed when the [Q2] check box is selected in the Dashboard Pane.

Opens the Resolution / Axis Setting Pane.

[P/A Factor Setting]

This menu is displayed when the [Detector] check box is selected in the Dashboard Pane.

Opens the P/A Factor Setting Pane.

[EM Setting]

This menu is displayed when the [Detector] check box is selected in the Dashboard Pane.

Opens the EM Setting Pane.

[Dead Time Calibration]

This menu is displayed when the [Detector] check box is selected in the Dashboard Pane, and [Options] > [System Functions] > [Dead Time Calibration] is selected in the [Settings] dialog box.

Opens the Dead Time Calibration Pane.

[Startup] group

This menu is displayed when the [Home] tab > [Startup] group > [Configuration] is selected.

[Startup Configuration]

Opens the Startup Pane.

[User Tune Configuration]

Opens the User Tune Pane.

[Acquisition] group

This menu is displayed when you open a batch.

[Setup]

Opens the Setup Pane.

[Tune Modes]

Opens the Tune Modes Pane.

[Element Selection]

Opens the Element Selection Pane.

[Sample Introduction]

Opens the Sample Introduction Pane.

[Agilent LC]

This menu is displayed when [System] > [Sample Introduction] > [Agilent LC] is selected in the [Settings] dialog box.

Opens the Agilent LC Pane.

[Agilent GC]

This menu is displayed when [System] > [Sample Introduction] > [Agilent GC] is selected in the [Settings] dialog box.

Opens the Agilent GC Pane.

[Monitor]

This menu is displayed when the [Home] tab > [Batch] group > [Advanced Option] is selected.

Opens the Monitor Pane.

[Analyte List]

This menu is displayed when [FullQuant Analysis] and [Isotope Dilution Analysis], or [Timechart] in [Analysis mode], are selected from the [Data Analysis Method] table in the Setup Pane.

Opens the Analyte List Pane.

[Calibration]

This menu is displayed when [FullQuant Analysis] is selected in the [Data Analysis Method] table in the Setup Pane.

Opens the Calibration Pane.

[SemiQuant]

This menu is displayed when [SemiQuant Analysis] is selected in the [Data Analysis Method] table in the Setup Pane.

Opens the SemiQuant Pane.

[Isotope Ratio]

This menu is displayed when [Isotope Ratio Analysis] is selected in the [Data Analysis Method] table in the Setup Pane.

Opens the Isotope Ratio Pane.

[QC]

FullQuant Outlier Pane is displayed when [FullQuant Analysis] is selected and [Intelligent Sequence] is cleared in the [Data Analysis Method] table on the Setup Pane.

QC Parameters Pane is displayed when [FullQuant Analysis] is selected and [Intelligent Sequence] is cleared.

[Single Particle]

This menu is displayed when you open a batch in Single Particle Analysis.

Opens the Single Particle Pane.

[Worklist Action]

This menu is displayed when the [Home] tab > [Batch] group > [Advanced Option] is selected.

Opens the Worklist Action Pane.

[Sequence] group

This menu is displayed when you open a batch.

[Sample List]

Opens the Sample List Pane (Sequence).

[Queue] group

[Acquisition Queue]

Opens the Acquisition Queue Pane, Sample List Pane (Queue), and Real Time Display Pane.

[Result] group

[Online Data Analysis]

Opens the [ICP-MSQQQ Data Analysis] Window.